湿度转换时应该判断是否大于100和小于0 #8

Closed
Ryan-CW-Code opened this issue Mar 20, 2025 · 2 comments
Closed

湿度转换时应该判断是否大于100和小于0 #8

Ryan-CW-Code opened this issue Mar 20, 2025 · 2 comments

Comments

@Ryan-CW-Code
Copy link

Version

No response

Describe the bug

在极端湿度的环境下,通过浮点数换算可能会超过100%或者低于0%。
数据手册简单的示例代码对湿度有高于100就等于100,低于0就为0的判断

Reproduce

No response

Expected behavior

No response

Additional context

No response

@libdriver
Copy link
Owner

Image
非常感谢您提出的宝贵建议,我们已经修复此BUG,您可以重新拉取或者下载版本为v1.0.5的驱动,LibDriver祝您身体健康,工作顺利!

@Ryan-CW-Code
Copy link
Author

感谢